What is a space all about? Atmosphere, people that inhabit and use it, the feeling of belonging? Is it about boundaries? Separating what is inside from what is outside? Space is all about you. What you consider important. We create the frame that shapes your vision, keeps it safe and makes it beautiful.

Technologies

ELVIAL's steps to perfection. A key factor in the rapid growth of ELVIAL has been its ongoing investment of substantial capital innovative ideas and the application of state-of-the-art technologies and totally vertical profile and system processing and production.
ELVIAL I2 TECHNOLOGY
ELVIAL PRE-ANODIZING 2IN1
ELVIAL I2 TECHNOLOGY
ELVIAL I2 TECHNOLOGY

Window Systems

ICONIC W77 AI² CE ICONIC W77 AI² CE_BS Iconic W77 AI² ML Iconic W77 AI² ML_BS
ICONIC W77 AI² CE ICONIC W77 AI² CE_BS ICONIC W77 AI² ML ICONIC W77 AI² ML_BS
DESIGN - - - -
System Depth mm 77 77 77 77
Min Face Height
Frame-Sash
mm 89 66 89 66
Min Face Height
Threshold-Sash
mm 79 56
Min Face Width
Middle Mullion
mm 154 107 154 78
Design Minimal Design
Linear Design
Minimal Design
Linear Design
Minimal Design
Linear Design
Minimal Design
Linear Design
PROPERTIES - - - -
Max Sash Height mm 2.800 2.400 2.800 2.400
Max Sash Width mm 1.600 1.200 1.600 1.200
Max Sash Weight kg 200 130 200 130
Max Glass
thickness
mm 70 46 or 32 70 46 or 32
Mechanism Type Multilock groove
mechanism [ML]
Multilock groove
mechanism [ML]
Multilock groove
mechanism [ML]
Multilock groove
mechanism [ML]
Surface Finishings All All All All
PERFORMANCE - - - -
Uf Value (≥)
EN ISO 10077-2
W/m²K 1.1 1.0 0.89 1.0
Air Permeability
EN 12207
Class 4 Class 4 Class 4 Class 4
Water Tightness
EN 12208
E1200 Ε1050 E1200 Ε1050
Wind Load Resistance
EN 12210
C5/B5 C5/B5 C5/B5 C5/B5
Sound Reduction
ISO 10140-2
50 50
Operating Force Class 2 Class 2 Class 2 Class 2
ENERGY
Uf value ( ≥)
EN ISO 10077-2
The Uf value measures the heat flow. The lower the Uf , the more efficient the profile you have chosen.
Air Permeability*
EN 1026; EN 12207
1
(150 Pa)
2
(300 Pa)
3
(450 Pa)
4
(600 Pa)
Water Tightness**
EN 1027;EN 12208
3A
(100 Pa)
4A
(150 Pa)
5A
(200 Pa)
6A
(250 Pa)
7A
(300 Pa)
8A
(450 Pa)
9A
(600 Pa)
E750
(750 Pa)
E1050
(1050 Pa)
E1200
(1200 Pa)
Wind Load Resistance***
EN 12211; EN 12210
1
(400 Pa)
2
(800 Pa)
3
(1200 Pa)
4
(1600 Pa)
5
(2000 Pa)
E
(>2000Pa)
Wind Load Resistance, frame deflection***
EN 12211; EN 12210
Α
(<l/150)
B
(<l/200)
C
(<l/300)
This table shows classes and values of performances, which can be achieved for specific configurations and opening types.
* The Air permeability is the measure of the ability of closed window or door to resist the uncontrolled flow of air at a certain pressure.
** The Water tightness in a window is its capacity to avoid water penetration.
*** The Wind-load resistance refers to the resistance of the closed doors and windows to wind pressure without any damages and functional impairment.There are up to 6 levels of wind resistance and 3 deflection classes.The higher the number, the stronger the wind-load resistance.
Iconic W77 ST AI²
ICONIC W77ST AI²
DESIGN -
System Depth mm 77
Min Face Height
Frame-Sash
mm 68
Min Face Width
Middle Mullion
mm 89
Design Minimal Design
Industrial Design
PROPERTIES -
Max Sash Height mm 2.400
Max Sash Width mm 900
Max Sash Weight kg 130
Max Glass
thickness
mm 56
Mechanism Type European groove
mechanism [CE]
Surface Finishings All
Essence W67 HI² CE Essence W67 HI² CE_BS Essence W67 HI² ML Essence W67 HI² ML_BS
ESSENCE W67 HI² CE ESSENCE W67 HI² CE_BS ESSENCE W67 HI² ML ESSENCE W67 HI² ML_BS
DESIGN - - - -
System Depth mm 67 67 67 67
Min Face Height
Frame-Sash
mm 89 66 89 66
Min Face Height
Threshold-Sash
mm 79 56
Min Face Width
Middle Mullion
mm 154 107 154 78
Design Linear Design Minimal Design
Linear Design
Linear Design Minimal Design
Linear Design
PROPERTIES - - - -
Max Sash Height mm 2.800 2.400 2.800 2.400
Max Sash Width mm 1.600 1.200 1.600 1.200
Max Sash Weight kg 200 130 200 130
Max Glass
thickness
mm 60 46 or 28 60 46 or 28
Mechanism Type European groove
mechanism [CE]
European groove
mechanism [CE]
Multilock groove
mechanism [ML]
Multilock groove
mechanism [ML]
Surface Finishings All All All All
PERFORMANCE - - - -
Uf Value (≥)
EN ISO 10077-2
W/m²K 1.2 1.8 1.2 1.8
Air Permeability
EN 12207
Class 4 Class 4 Class 4 Class 4
Water Tightness
EN 12208
E1050 E1050 E1050 E1050
Wind Load Resistance
EN 12210
C5/B5 C5/B5 C5/B5 C5/B5
Sound Reduction
ISO 10140-2
40 40 40 40
Operating Force Class 2 Class 2 Class 2 Class 2
ENERGY
Uf value ( ≥)
EN ISO 10077-2
The Uf value measures the heat flow. The lower the Uf , the more efficient the profile you have chosen.
Air Permeability*
EN 1026; EN 12207
1
(150 Pa)
2
(300 Pa)
3
(600 Pa)
4
(600 Pa)
Water Tightness**
EN 1027;EN 12208
3A
(100 Pa)
4A
(150 Pa)
5A
(200 Pa)
6A
(250 Pa)
7A
(300 Pa)
8A
(450 Pa)
9A
(600 Pa)
E750
(750 Pa)
E1050
(1050 Pa)
E1200
(1200 Pa)
Wind Load Resistance***
EN 12211; EN 12210
1
(400 Pa)
2
(800 Pa)
3
(1200 Pa)
4
(1600 Pa)
5
(2000 Pa)
E
(>2000Pa)
Wind Load Resistance, to Frame Deflection***
EN 12211; EN 12210
Α
(<l/150)
B
(<l/200)
C
(<l/300)
This table shows classes and values of performances, which can be achieved for specific configurations and opening types.
* The Air permeability is the measure of the ability of closed window or door to resist the uncontrolled flow of air at a certain pressure.
** The Water tightness in a window is its capacity to avoid water penetration.
*** The Wind-load resistance refers to the resistance of the closed doors and windows to wind pressure without any damages and functional impairment.There are up to 6 levels of wind resistance and 3 deflection classes.The higher the number, the stronger the wind-load resistance.
Essence W67ST HI².CE Essence W67ST HI² ML
ESSENCE W67ST HI² CE ESSENCE W67ST HI² ML
DESIGN - -
System Depth mm 67 67
Min Face Height
Frame-Sash
mm 75.2 75.2
Min Face Width
Middle Mullion
mm 112.7 125.9
Design ROUNDED Design [RD] LINEAR Design [LD]
PROPERTIES - -
Max Sash Height mm 2.300 2.300
Max Sash Width mm 800 800
Max Sash Weight kg 80 80
Max Glass
thickness
mm 46 46
Mechanism Type European groove
mechanism [CE]
Multilock groove
mechanism [ML]
Surface Finishings All All
ELVIAL W59 SI² CE ELVIAL W59 SI² CE_RD ELVIAL W59 SI² ML ELVIAL W59 SI² ML_RD ELVIAL W60 SI².ML_BS
ELVIAL W59 SI² CE ELVIAL W59 SI² CE_RD ELVIAL W59 SI² ML ELVIAL W59 SI² ML_RD ELVIAL W60 SI².ML_BS
DESIGN - - - - -
System Depth mm 58.6 69 58.6 69 60
Min Face Height
Frame-Sash
mm 94.1 94.1 94.1 94.1 69
Min Face Height
Threshold-Sash
mm 107.5
Min Face Width
Middle Mullion
mm 155.7 155.7 155.7 155.7 93.5
Design Linear Design [LD] Rounded Design [RD] LINEAR Design [LD] Rounded Design [RD] Minimal Design
Linear Design
PROPERTIES - - - - -
Max Sash Height mm 2.250 2.250 2.250 2.250 2.100
Max Sash Width mm 1.000 1.000 1.000 1.000 1.000
Max Sash Weight kg 90 90 90 90 100
Max Glass
thickness
mm 46 35 46 35 24
Mechanism Type European groove
mechanism [CE]
European groove
mechanism [CE]
Multilock groove
mechanism [ML]
Multilock groove
mechanism [ML]
Multilock groove mechanism [ML]
Surface Finishings All All All All All
PERFORMANCE - - - - -
Uf Value (≥)
EN ISO 10077-2
W/m²K 2.16 2.5 2.16 2.5 2.5
Air Permeability
EN 12207
Class 4 Class 4 Class 4 Class 4 Class 4
Water Tightness
EN 12208
E1650 E1650 E1650 E1650 E1050
Wind Load Resistance
EN 12210
C4/B4 C4/B4 C4/B4 C4/B4 C5/B5
Operating Force Class 1
ENERGY
Uf value ( ≥)
EN ISO 10077-2
The Uf value measures the heat flow. The lower the Uf , the more efficient the profile you have chosen.
Air Permeability*
EN 1026; EN 12207
1
(150 Pa)
2
(300 Pa)
3
(600 Pa)
4
(600 Pa)
Water Tightness**
EN 1027;EN 12208
7A
(300 Pa)
8A
(450 Pa)
9A
(600 Pa)
E750
(750 Pa)
E900
(900 Pa)
E1050
(1050 Pa)
E1200
(1200 Pa)
E1350
(1350 Pa)
E1500
(1500 Pa)
E1650
(1650 Pa)
Wind Load Resistance***
EN 12211; EN 12210
1
(400 Pa)
2
(800 Pa)
3
(1200 Pa)
4
(1600 Pa)
5
(2000 Pa)
E
(>2000Pa)
Wind Load Resistance, to Frame Deflection***
EN 12211; EN 12210
Α
(<l/150)
B
(<l/200)
C
(<l/300)
This table shows classes and values of performances, which can be achieved for specific configurations and opening types.
* The Air permeability is the measure of the ability of closed window or door to resist the uncontrolled flow of air at a certain pressure.
** The Water tightness in a window is its capacity to avoid water penetration.
*** The Wind-load resistance refers to the resistance of the closed doors and windows to wind pressure without any damages and functional impairment.There are up to 6 levels of wind resistance and 3 deflection classes.The higher the number, the stronger the wind-load resistance.
ELVIAL W89 PHI².CE ELVIAL W89 PHI².ML
ELVIAL W89 PHI².CE ELVIAL W89 PHI².ML
DESIGN - -
System Depth mm 89 89
Min Face Height
Frame-Sash
mm 89 89
Min Face Width
Middle Mullion
mm 154 154
Design LINEAR Design [LD] LINEAR Design [LD]
PROPERTIES - -
Max Sash Height mm 2.800 2.800
Max Sash Width mm 1.600 1600
Max Sash Weight kg 200 200
Max Glass
thickness
mm 83 83
Mechanism Type European groove
mechanism [CE]
Multilock groove
mechanism [ML]
Surface Finishings All All
PERFORMANCE - -
ELVIAL W92 HI² AW
ELVIAL W92 HI² AW
DESIGN -
System Depth mm 92
Min Face Height
Frame-Sash
mm 109.5
Min Face Width
Middle Mullion
mm 164.5
Design LINEAR Design [LD]
PROPERTIES -
Max Sash Height mm 2.400
Max Sash Width mm 1.600
Max Sash Weight kg 130
Max Glass
thickness
mm 48
Mechanism Type Alu-Wood
mechanism [AW]
Surface Finishings All
PERFORMANCE -
Uf Value (≥)
EN ISO 10077-2
W/m²K 1.4
Air Permeability
EN 12207
Class 4
Water Tightness
EN 12208
Class 7A
Wind Load Resistance
EN 12210
Class C4/B4
ENERGY
Uf value ( ≥)
EN ISO 10077-2
The Uf value measures the heat flow. The lower the Uf , the more efficient the profile you have chosen.
Air Permeability*
EN 1026; EN 12207
1
(150 Pa)
2
(300 Pa)
3
(600 Pa)
4
(600 Pa)
Water Tightness**
EN 1027;EN 12208
4A
(150 Pa)
5A
(200 Pa)
6A
(250 Pa)
7A
(300 Pa)
8A
(450 Pa)
9A
(600 Pa)
E750
(750 Pa)
E900
(900 Pa)
E1050
(1050 Pa)
E1200
(1200 Pa)
Wind Load Resistance***
EN 12211; EN 12210
1
(400 Pa)
2
(800 Pa)
3
(1200 Pa)
4
(1600 Pa)
5
(2000 Pa)
E
(>2000Pa)
Wind Load Resistance, to Frame Deflection***
EN 12211; EN 12210
Α
(<l/150)
B
(<l/200)
C
(<l/300)
This table shows classes and values of performances, which can be achieved for specific configurations and opening types.
* The Air permeability is the measure of the ability of closed window or door to resist the uncontrolled flow of air at a certain pressure.
** The Water tightness in a window is its capacity to avoid water penetration.
*** The Wind-load resistance refers to the resistance of the closed doors and windows to wind pressure without any damages and functional impairment.There are up to 6 levels of wind resistance and 3 deflection classes.The higher the number, the stronger the wind-load resistance.
Elvial Facebook Instagram Twitter YouTube Pinterest Pinterest Google Plus LinkedIn Previous Next
espa espa