WINDOWS
WINDOWS

More than meets the eye

What is a space all about? Atmosphere, people that inhabit and use it, the feeling of belonging? Is it about boundaries? Separating what is inside from what is outside? Space is all about you. What you consider important. We create the frame that shapes your vision, keeps it safe and makes it beautiful.

ELVIAL I² TECHNOLOGY
ELVIAL PRE-ANODIZING 2IN1
ELVIAL I² TECHNOLOGY
ELVIAL I² TECHNOLOGY

Window Systems

ICONIC W77 AI² CE ICONIC W77 AI² ML ICONIC W77BS AI² CE ICONIC W77BS AI² ML
ICONIC W77 AI² CE ICONIC W77 AI² ML ICONIC W77BS AI² CE ICONIC W77BS AI² ML
DESIGN
- - - -
System Depth in 3 116 3 116 3 116 3 116
Min Face Height Frame-Sash in 3 816 3 816 2 916 2 916
Min Face Height Threshold-Sash in 3 18 2 316 2 316
Min Face Width Middle Mullion in 6 116 6 116 4 14 3 116
Design Minimal Design
Linear Design
Minimal Design
Linear Design
Minimal Design
Linear Design
Minimal Design
Linear Design
PROPERTIES
- - - -
Max Sash Height in 110 14 110 14 98 716 98 716
Max Sash Width in 55 18 55 18 55 18 55 18
Max Sash Weight lb 397 397 287 287
Max Glass Thickness in 2 34 2 34 1 1316 in or 1 14 1 1316 or 1 14
Mechanism Type Multilock groove
mechanism [ML]
Multilock groove
mechanism [ML]
Multilock groove
mechanism [ML]
Multilock groove
mechanism [ML]
Surface Finishings All All All All
PERFORMANCE
- - - -
Uf Value (≥) BTU/hr·ft²·°F 0.74 0.13 0.18 0.18
Air Permeability Class 4 Class 4 Class 4 Class 4
Watertightness E1200 E1200 Ε1050 Ε1050
Resistance to Wind Load psf C5/B5 C5/B5 C5/B5 C5/B5
Sound Reduction 50 50
Operating Forces
ENERGY
Uf value ( ≥)
EN ISO 10077-2
The Uf value measures the heat flow. The lower the Uf , the more efficient the profile you have chosen.
Air Permeability*
EN 1026; EN 12207
1
(150 Pa)
2
(300 Pa)
3
(450 Pa)
4
(600 Pa)
Water Tightness**
EN 1027;EN 12208
3A
(100 Pa)
4A
(150 Pa)
5A
(200 Pa)
6A
(250 Pa)
7A
(300 Pa)
8A
(450 Pa)
9A
(600 Pa)
E750
(750 Pa)
E1050
(1050 Pa)
E1200
(1200 Pa)
Wind Load Resistance***
EN 12211; EN 12210
1
(400 Pa)
2
(800 Pa)
3
(1200 Pa)
4
(1600 Pa)
5
(2000 Pa)
E
(>2000Pa)
Wind Load Resistance, frame deflection***
EN 12211; EN 12210
Α
(<l/150)
B
(<l/200)
C
(<l/300)
This table shows classes and values of performances, which can be achieved for specific configurations and opening types.
* The Air permeability is the measure of the ability of closed window or door to resist the uncontrolled flow of air at a certain pressure.
** The Water tightness in a window is its capacity to avoid water penetration.
*** The Wind-load resistance refers to the resistance of the closed doors and windows to wind pressure without any damages and functional impairment.There are up to 6 levels of wind resistance and 3 deflection classes.The higher the number, the stronger the wind-load resistance.
ICONIC W77ST AI²
ICONIC W77ST AI²
DESIGN
-
System Depth in 316
Min Face Height Frame-Sash in 2 1116
Min Face Height Threshold-Sash in
Min Face Width Middle Mullion in 3 816
Design Minimal Design
Industrial Design
PROPERTIES
-
Max Sash Height in 94 12
Max Sash Width in 47 14
Max Sash Weight lb 31lbs
Max Glass Thickness in 2 316
Mechanism Type European groove
mechanism [CE]
Surface Finishings All
ESSENCE W67 HI² CE ESSENCE W67 HI² ML ESSENCE W67BS HI² CE ESSENCE W67BS HI² ML
ESSENCE W67 HI² CE ESSENCE W67 HI² ML ESSENCE W67BS HI² CE ESSENCE W67BS HI² ML
DESIGN
- - - -
System Depth in 2 1016 2 1016 2 1016 2 1016
Min Face Height Frame-Sash in 3 816 3 816 2 1016 2 1016
Min Face Height Threshold-Sash in 3 216 2 316
Min Face Width Middle Mullion in 6 116 6 116 4 316 3 116
Design Linear Design Linear Design Minimal Design
Linear Design
Minimal Design
Linear Design
PROPERTIES
- - - -
Max Sash Height in 110 416 110 416 98 716 98 716
Max Sash Width in 55 18 55 216 55 18 55 216
Max Sash Weight lb 397 397 287 287
Max Glass Thickness in 2 38 2 616 1 1316 or 1 1016 or 1 18 1 1316 or 1 58 or 1 18
Mechanism Type European groove
mechanism [CE]
Multilock groove
mechanism [ML]
European groove
mechanism [CE]
Multilock groove
mechanism [ML]
Surface Finishings All All All All
PERFORMANCE
- - - -
Uf Value (≥) BTU/hr·ft²·°F 0.19 0.19 0.21 0.21
Air Permeability Class 4 Class 4 Class 4 Class 4
Watertightness E1350 E1350 E1050 E1050
Resistance to Wind Load psf C5/B5 C5/B5 C5/B5 C5/B5
Sound Reduction 44 44 38 38
Operating Forces Class 1 Class 1
ENERGY
Uf value ( ≥)
EN ISO 10077-2
The Uf value measures the heat flow. The lower the Uf , the more efficient the profile you have chosen.
Air Permeability*
EN 1026; EN 12207
1
(150 Pa)
2
(300 Pa)
3
(600 Pa)
4
(600 Pa)
Water Tightness**
EN 1027;EN 12208
3A
(100 Pa)
4A
(150 Pa)
5A
(200 Pa)
6A
(250 Pa)
7A
(300 Pa)
8A
(450 Pa)
9A
(600 Pa)
E750
(750 Pa)
E1050
(1050 Pa)
E1200
(1200 Pa)
Wind Load Resistance***
EN 12211; EN 12210
1
(400 Pa)
2
(800 Pa)
3
(1200 Pa)
4
(1600 Pa)
5
(2000 Pa)
E
(>2000Pa)
Wind Load Resistance, to Frame Deflection***
EN 12211; EN 12210
Α
(<l/150)
B
(<l/200)
C
(<l/300)
This table shows classes and values of performances, which can be achieved for specific configurations and opening types.
* The Air permeability is the measure of the ability of closed window or door to resist the uncontrolled flow of air at a certain pressure.
** The Water tightness in a window is its capacity to avoid water penetration.
*** The Wind-load resistance refers to the resistance of the closed doors and windows to wind pressure without any damages and functional impairment.There are up to 6 levels of wind resistance and 3 deflection classes.The higher the number, the stronger the wind-load resistance.
ESSENCE W67ST HI² CE ESSENCE W67ST HI² ML
ESSENCE W67ST HI² CE ESSENCE W67ST HI² ML
DESIGN
- -
System Depth in 2 1016 2 1016
Min Face Height Frame-Sash in 2 1516 2 1516
Min Face Height Threshold-Sash in
Min Face Width Middle Mullion in 4 716 4 716
Design ROUNDED Design [RD] LINEAR Design [LD]
PROPERTIES
- -
Max Sash Height in 90 916 94 816
Max Sash Width in 31 816 47 416
Max Sash Weight lb 176 331
Max Glass Thickness in 1 1316 1 1316
Mechanism Type European groove
mechanism [CE]
Multilock groove
mechanism [ML]
Surface Finishings All All
ELVIAL W59 SI² CE ELVIAL W59 SI² CE_RD ELVIAL W59 SI² ML ELVIAL W59 SI² ML_RD ELVIAL W60BS SI²
ELVIAL W59 SI² CE ELVIAL W59 SI² CE_RD ELVIAL W59 SI² ML ELVIAL W59 SI² ML_RD ELVIAL W60BS SI²
DESIGN
- - - - -
System Depth in 2 516 2 1116 2 516 2 1116 2 616
Min Face Height Frame-Sash in 3 1116 3 1116 3 1116 3 1116 2 1116
Min Face Height Threshold-Sash in 4 316 4 116 4 316 4 116
Min Face Width Middle Mullion in 6 216 6 216 6 216 6 216 3 1116
Design Linear Design [LD] Rounded Design [RD] LINEAR Design [LD] Rounded Design [RD] Minimal Design
Linear Design
PROPERTIES
- - - - -
Max Sash Height in 90 916 90 916 90 916 90 916 98 716
Max Sash Width in 39 616 39 616 39 616 39 616 39 616
Max Sash Weight lb 287 287 287 287 220
Max Glass Thickness in 1 1316 1 716 1 1316 1 716 0 1516
Mechanism Type European groove
mechanism [CE]
European groove
mechanism [CE]
Multilock groove
mechanism [ML]
Multilock groove
mechanism [ML]
Multilock groove mechanism [ML]
Surface Finishings All All All All All
PERFORMANCE
- - - - -
Uf Value (≥) BTU/hr·ft²·°F 0.32 0.44 0.32 0.44 0.44
Air Permeability Class 4 Class 4 Class 4 Class 4 Class 4
Watertightness E1650 E1650 E1650 E1650 E1050
Resistance to Wind Load psf C5/B5 C5/B5 C5/B5 C5/B5 C5/B5
Sound Reduction 40 40
Operating Forces
ENERGY
Uf value ( ≥)
EN ISO 10077-2
The Uf value measures the heat flow. The lower the Uf , the more efficient the profile you have chosen.
Air Permeability*
EN 1026; EN 12207
1
(150 Pa)
2
(300 Pa)
3
(600 Pa)
4
(600 Pa)
Water Tightness**
EN 1027;EN 12208
7A
(300 Pa)
8A
(450 Pa)
9A
(600 Pa)
E750
(750 Pa)
E900
(900 Pa)
E1050
(1050 Pa)
E1200
(1200 Pa)
E1350
(1350 Pa)
E1500
(1500 Pa)
E1650
(1650 Pa)
Wind Load Resistance***
EN 12211; EN 12210
1
(400 Pa)
2
(800 Pa)
3
(1200 Pa)
4
(1600 Pa)
5
(2000 Pa)
E
(>2000Pa)
Wind Load Resistance, to Frame Deflection***
EN 12211; EN 12210
Α
(<l/150)
B
(<l/200)
C
(<l/300)
This table shows classes and values of performances, which can be achieved for specific configurations and opening types.
* The Air permeability is the measure of the ability of closed window or door to resist the uncontrolled flow of air at a certain pressure.
** The Water tightness in a window is its capacity to avoid water penetration.
*** The Wind-load resistance refers to the resistance of the closed doors and windows to wind pressure without any damages and functional impairment.There are up to 6 levels of wind resistance and 3 deflection classes.The higher the number, the stronger the wind-load resistance.
ELVIAL W89 PHI² CE ELVIAL W89 PHI² ML
ELVIAL W89 PHI² CE ELVIAL W89 PHI² ML
DESIGN
- -
System Depth in 3 816 3 816
Min Face Height Frame-Sash in 3 816 3 12
Min Face Height Threshold-Sash in
Min Face Width Middle Mullion in 6 116 6 116
Design LINEAR Design [LD] LINEAR Design [LD]
PROPERTIES
- -
Max Sash Height in 110 416 110 416
Max Sash Width in 62 1516 62 1516
Max Sash Weight lb 441 441
Max Glass Thickness in 3 416 3 416
Mechanism Type European groove
mechanism [CE]
Multilock groove
mechanism [ML]
Surface Finishings All All
PERFORMANCE
- -
Uf Value (≥) BTU/hr·ft²·°F 0.11 0.11
Air Permeability Class 4 Class 4
Watertightness E1050 E1050
Resistance to Wind Load psf C4/B4 C4/B4
Sound Reduction
Operating Forces
ELVIAL W92 HI² AW
ELVIAL W92 HI² AW
DESIGN
-
System Depth in 3 1016
Min Face Height Frame-Sash in 4 516
Min Face Height Threshold-Sash in
Min Face Width Middle Mullion in 6 716
Design LINEAR Design [LD]
PROPERTIES
-
Max Sash Height in 94 816
Max Sash Width in 62 1516
Max Sash Weight lb 287
Max Glass Thickness in 1 1416
Mechanism Type Alu-Wood
mechanism [AW]
Surface Finishings All
PERFORMANCE
-
Uf Value (≥) BTU/hr·ft²·°F 0.19
Air Permeability Class 4
Watertightness 7A
Resistance to Wind Load psf C4/B4
Sound Reduction
Operating Forces
ENERGY
Uf value ( ≥)
EN ISO 10077-2
The Uf value measures the heat flow. The lower the Uf , the more efficient the profile you have chosen.
Air Permeability*
EN 1026; EN 12207
1
(150 Pa)
2
(300 Pa)
3
(600 Pa)
4
(600 Pa)
Water Tightness**
EN 1027;EN 12208
4A
(150 Pa)
5A
(200 Pa)
6A
(250 Pa)
7A
(300 Pa)
8A
(450 Pa)
9A
(600 Pa)
E750
(750 Pa)
E900
(900 Pa)
E1050
(1050 Pa)
E1200
(1200 Pa)
Wind Load Resistance***
EN 12211; EN 12210
1
(400 Pa)
2
(800 Pa)
3
(1200 Pa)
4
(1600 Pa)
5
(2000 Pa)
E
(>2000Pa)
Wind Load Resistance, to Frame Deflection***
EN 12211; EN 12210
Α
(<l/150)
B
(<l/200)
C
(<l/300)
This table shows classes and values of performances, which can be achieved for specific configurations and opening types.
* The Air permeability is the measure of the ability of closed window or door to resist the uncontrolled flow of air at a certain pressure.
** The Water tightness in a window is its capacity to avoid water penetration.
*** The Wind-load resistance refers to the resistance of the closed doors and windows to wind pressure without any damages and functional impairment.There are up to 6 levels of wind resistance and 3 deflection classes.The higher the number, the stronger the wind-load resistance.
Elvial Facebook Instagram Twitter YouTube Pinterest Pinterest Google Plus LinkedIn Previous Next