SLIDINGS
SLIDINGS

More than meets the eye

What is a space all about? Atmosphere, people that inhabit and use it, the feeling of belonging? Is it about boundaries? Separating what is inside from what is outside? Space is all about you. What you consider important. We create the frame that shapes your vision, keeps it safe and makes it beautiful.

ELVIAL I² TECHNOLOGY
ELVIAL PRE-ANODIZING 2IN1
ELVIAL I² TECHNOLOGY
ELVIAL I² TECHNOLOGY

Sliding Systems

MINIMAL LOOK SL68 AI² MINIMAL LOOK SL52 HI²
MINIMAL LOOK SL68 AI² MINIMAL LOOK SL52 HI²
DESIGN
- -
Sash Depth in 2 1116 2 116
Visible Height Standard Edition in 3 116 3 116
Visible Height Infloor Edition in 1 38 1 38
Middle Mullion Width Successive in 1 38 1 38
Meeting Stile Construction Width in 4 516 4 516
Middle Mullion Width Fixed T in - 1 38
Design Minimal Design
Linear Design
Minimal Design
Linear Design
PROPERTIES
- -
Max Sash Height in 118 18 118 18
Max Sash Width in 118 18 118 18
Max Sash Weight lb 882 882
Max Glass Thickness in 1 1416 1 14
Mechanism Type Sliding Sliding
Surface Finishings All All
PERFORMANCE
- -
Uf Value (≥) BTU/hr·ft²·°F
Air Permeability Class 4 Class 4
Watertightness Class 7A Class 7A
Resistance to Wind Load psf C3 / C3 C3 / C3
Sound Reduction
Operating Forces Class 1 Class 1
ENERGY
Uf value ( ≥)
EN ISO 10077-2
The Uf value measures the heat flow. The lower the Uf , the more efficient the profile you have chosen.
Air Permeability*
EN 1026; EN 12207
1
(150 Pa)
2
(300 Pa)
3
(600 Pa)
4
(600 Pa)
Water Tightness**
EN 1027;EN 12208
4A
(150 Pa)
5A
(200 Pa)
6A
(250 Pa)
7A
(300 Pa)
8A
(450 Pa)
9A
(600 Pa)
E750
(750 Pa)
E1050
(1050 Pa)
E1200
(1200 Pa)
Wind Load Resistance***
EN 12211; EN 12210
1
(400 Pa)
2
(800 Pa)
3
(1200 Pa)
4
(1600 Pa)
5
(2000 Pa)
E
(>2000Pa)
Wind Load Resistance, frame deflection***
EN 12211; EN 12210
Α
(<l/150)
B
(<l/200)
C
(<l/300)
Operating Force
ΕΝ 13115
0 1 2
This table shows classes and values of performances, which can be achieved for specific configurations and opening types.
* The Air permeability is the measure of the ability of closed window or door to resist the uncontrolled flow of air at a certain pressure.
** The Water tightness in a window is its capacity to avoid water penetration.
*** The Wind-load resistance refers to the resistance of the closed doors and windows to wind pressure without any damages and functional impairment.There are up to 6 levels of wind resistance and 3 deflection classes.The higher the number, the stronger the wind-load resistance.
ELVIAL SL60 HI² CLASSIC ESSENCE SL60 HI² ESSENCE SL60 HI² FLAT EDITION
ELVIAL SL60 HI² CLASSIC ESSENCE SL60 HI² ESSENCE SL60 HI² FLAT EDITION
DESIGN
- - -
Sash Depth in 2 616 2 616 2 616
Visible Height Standard Edition in 5 316, 4 1316 5, 4 1016 4 1516, 4 816
Visible Height Infloor Edition in 3 716, 3 3 716, 3 016 3 1216, 3 616
Middle Mullion Width Successive in 4 216, 3 1216, 1 1416 4 216, 3 1216, 1 1416 4 216, 3 1216, 1 1416
Meeting Stile Construction Width in 7 1316, 7 016 7 1316, 7 016 7 1316, 7
Middle Mullion Width Fixed T in 3 1216
Design Linear Design [LD] Linear Design [LD] Linear Design [LD]
PROPERTIES
- - -
Max Sash Height in 137 1316 137 1316 137 1316
Max Sash Width in 118 18 118 216 118 18
Max Sash Weight lb 970 970 970
Max Glass Thickness in 1 1316 1 1316 1 1316
Mechanism Type Lift & Slide/Sliding Lift & Slide Lift & Slide
Surface Finishings All All All
PERFORMANCE
- - -
Uf Value (≥) BTU/hr·ft²·°F 0.42 0.46 0.49
Air Permeability Class 4 Class 4 Class 4
Watertightness E1200 9A 7A
Resistance to Wind Load psf C2/B3 C5/B5 B3
Sound Reduction 45
Operating Forces Class 1 Class 2
ELVIAL SL50 HI² CLASSIC ESSENCE SL50 HI² FLAT EDITION
ELVIAL SL50 HI² CLASSIC ESSENCE SL50 HI² FLAT EDITION
DESIGN
- -
Sash Depth in 1 1516 1 1516
Visible Height Standard Edition in 4  3132|4  516, 4  516|3  1116 4 1016
Visible Height Infloor Edition in 3 18, 2  816 3 816
Middle Mullion Width Successive in 3  78, 1  78, 1 3 1416, 1 1416, 1
Meeting Stile Construction Width in 7  14, 6 7 416
Middle Mullion Width Fixed T in 3  78, 1  78
Design Linear Design [LD] Linear Design [LD]
PROPERTIES
- -
Max Sash Height in 137 1316 137 1316
Max Sash Width in 118  18 118 216
Max Sash Weight lb 882 882
Max Glass Thickness in 1 716, 1 516 1 716, 1 516
Mechanism Type Lift & Slide/Sliding Lift & Slide
Surface Finishings All All
PERFORMANCE
- -
Uf Value (≥) BTU/hr·ft²·°F 0.42 0.42
Uw value (=) BTU/hr·ft²·°F 0.23 0.25
Air Permeability Class 4 Class 4
Watertightness E900 7A
Resistance to Wind Load psf C4/B4 C2/B2
Sound Reduction 44
Operating Forces Class 1 Class 1
ELVIAL SL46 SI² CLASSIC ELVIAL SL46 SI² FLAT EDITION
ELVIAL SL46 SI² CLASSIC ELVIAL SL46 SI² FLAT EDITION
DESIGN
- -
Sash Depth in 1 1316 1 1316
Visible Height Standard Edition in 4 1316 3 78
Visible Height Infloor Edition in 3 116
Middle Mullion Width Successive in 3 12, 2 316 3 816, 2 316
Meeting Stile Construction Width in 7 716 7 716
Middle Mullion Width Fixed T in 2 316
Design LINEAR Design [LD] LINEAR Design [LD]
PROPERTIES
- -
Max Sash Height in 110 14 110 14
Max Sash Width in 78 34 78 34
Max Sash Weight lb 882 882
Max Glass Thickness in 1 316 1 316
Mechanism Type Lift&Slide / Sliding Lift&Slide / Sliding
Surface Finishings All All
PERFORMANCE
- -
Uf Value (≥) BTU/hr·ft²·°F 0.72 0.59
Air Permeability Class 4 Class 4
Watertightness 4A 7A
Resistance to Wind Load psf C2/B2 C2/B2
Sound Reduction 39 38
Operating Forces
ENERGY
Uf value ( ≥)
EN ISO 10077-2
The Uf value measures the heat flow. The lower the Uf , the more efficient the profile you have chosen.
Air Permeability*
EN 1026; EN 12207
1
(150 Pa)
2
(300 Pa)
3
(600 Pa)
4
(600 Pa)
Water Tightness**
EN 1027;EN 12208
4A
(150 Pa)
5A
(200 Pa)
6A
(250 Pa)
7A
(300 Pa)
8A
(450 Pa)
9A
(600 Pa)
E750
(750 Pa)
E1050
(1050 Pa)
E1200
(1200 Pa)
Wind Load Resistance***
EN 12211; EN 12210
1
(400 Pa)
2
(800 Pa)
3
(1200 Pa)
4
(1600 Pa)
5
(2000 Pa)
E
(>2000Pa)
Wind Load Resistance, frame deflection***
EN 12211; EN 12210
Α
(<l/150)
B
(<l/200)
C
(<l/300)
This table shows classes and values of performances, which can be achieved for specific configurations and opening types.
* The Air permeability is the measure of the ability of closed window or door to resist the uncontrolled flow of air at a certain pressure.
** The Water tightness in a window is its capacity to avoid water penetration.
*** The Wind-load resistance refers to the resistance of the closed doors and windows to wind pressure without any damages and functional impairment.There are up to 6 levels of wind resistance and 3 deflection classes.The higher the number, the stronger the wind-load resistance.
ELVIAL SL46 SI²_MD
ELVIAL SL46 SI²_MD
DESIGN
-
Sash Depth in 1 1316
Visible Height Standard Edition in 3 316
Visible Height Infloor Edition in 2 516
Middle Mullion Width Successive in 2 316
Design LINEAR Design [LD]
PROPERTIES
-
Max Sash Height in 90 916
Max Sash Width in 47 14
Max Sash Weight lb 220
Max Glass Thickness in 1 316
Mechanism Type INLINE Sliding
Surface Finishings All
ELVIAL SL33 CLASSIC ELVIAL SL33 FLAT EDITION ELVIAL SL33_MD
ELVIAL SL33 CLASSIC ELVIAL SL33 FLAT EDITION ELVIAL SL33_MD
DESIGN
- - -
Sash Depth in 1 516 1 516 1 516
Visible Height Standard Edition in 4 1116, 4 316 4 016, 3 716 4 716, 3 1516
Middle Mullion Width Successive in 3 58, 3 18, 2 316, 1 3 1016, 3 216, 2 316, 1 3 58, 3 18, 2 316, 1
Meeting Stile Construction Width in 7 58, 6 58 7 1016, 6 1016 7 58, 6 58
Middle Mullion Width Fixed T in 2 316
Design Linear Design [LD] Linear Design [LD] Linear Design [LD]
PROPERTIES
- - -
Max Sash Height in 94 12 94 816 94 12
Max Sash Width in 51 316 51 316 51 316
Max Sash Weight lb 265 265 265
Max Glass Thickness in 0 1516 0 1516 0 1516
Mechanism Type Sliding Sliding Sliding
Surface Finishings All All All
PERFORMANCE
- - -
Uf Value (≥) BTU/hr·ft²·°F 0.61 0.61 0.66
Uw value (=) BTU/hr·ft²·°F 0.30 0.28 0.30
Air Permeability Class 3
Watertightness 5A
Resistance to Wind Load psf C3/B3
Sound Reduction
Operating Forces Class 1
Elvial Facebook Instagram Twitter YouTube Pinterest Pinterest Google Plus LinkedIn Previous Next