What is a space all about? Atmosphere, people that inhabit and use it, the feeling of belonging? Is it about boundaries? Separating what is inside from what is outside? Space is all about you. What you consider important. We create the frame that shapes your vision, keeps it safe and makes it beautiful.

Technologies

ELVIAL's steps to perfection. A key factor in the rapid growth of ELVIAL has been its ongoing investment of substantial capital innovative ideas and the application of state-of-the-art technologies and totally vertical profile and system processing and production.
ELVIAL I² TECHNOLOGY
ELVIAL PRE-ANODIZING 2IN1
ELVIAL I² TECHNOLOGY
ELVIAL I2 TECHNOLOGY

Sliding Systems

MINIMAL LOOK SL68 AI² MINIMAL LOOK SL52 HI²
MINIMAL LOOK SL68 AI² MINIMAL LOOK SL52 HI²
DESIGN
- -
Sash Depth mm 68 52
Visible Height Standard Edition mm 77 77
Visible Height Infloor Edition mm 35 35
Middle Mullion Width Successive mm 35 35
Meeting Stile Construction Width mm 109 109
Middle Mullion Width Fixed T mm - 35
Design Minimal Design
Linear Design
Minimal Design
Linear Design
PROPERTIES
- -
Max Sash Height mm 3.000 3.000
Max Sash Width mm 3.000 3.000
Max Sash Weight kg 400 400
Max Glass Thickness mm 48 32
Mechanism Type Sliding Sliding
Surface Finishings All All
PERFORMANCE
- -
Uf Value (≥)
Air Permeability Class 4 Class 4
Water Tightness Class 7A Class 7A
Wind Load Resistance C3 / C3 C3 / C3
Sound Reduction
Operating Force Class 1 Class 1
ENERGY
Uf value ( ≥)
EN ISO 10077-2
The Uf value measures the heat flow. The lower the Uf , the more efficient the profile you have chosen.
Air Permeability*
EN 1026; EN 12207
1
(150 Pa)
2
(300 Pa)
3
(600 Pa)
4
(600 Pa)
Water Tightness**
EN 1027;EN 12208
4A
(150 Pa)
5A
(200 Pa)
6A
(250 Pa)
7A
(300 Pa)
8A
(450 Pa)
9A
(600 Pa)
E750
(750 Pa)
E1050
(1050 Pa)
E1200
(1200 Pa)
Wind Load Resistance***
EN 12211; EN 12210
1
(400 Pa)
2
(800 Pa)
3
(1200 Pa)
4
(1600 Pa)
5
(2000 Pa)
E
(>2000Pa)
Wind Load Resistance, frame deflection***
EN 12211; EN 12210
Α
(<l/150)
B
(<l/200)
C
(<l/300)
Operating Force
ΕΝ 13115
0 1 2
This table shows classes and values of performances, which can be achieved for specific configurations and opening types.
* The Air permeability is the measure of the ability of closed window or door to resist the uncontrolled flow of air at a certain pressure.
** The Water tightness in a window is its capacity to avoid water penetration.
*** The Wind-load resistance refers to the resistance of the closed doors and windows to wind pressure without any damages and functional impairment.There are up to 6 levels of wind resistance and 3 deflection classes.The higher the number, the stronger the wind-load resistance.
ELVIAL SL60 HI² Classic ESSENCE SL60 HI² ESSENCE SL60 HI² Flat Edition
ELVIAL SL60 HI² Classic ESSENCE SL60 HI² ESSENCE SL60 HI² Flat Edition
DESIGN
- - -
Sash Depth mm 60 60 60
Visible Height Standard Edition mm 132, 122 127, 117 125, 115
Visible Height Infloor Edition mm 87, 77 87, 77 95, 85
Middle Mullion Width Successive mm 105, 95, 48 105, 95, 48 105, 95, 48
Meeting Stile Construction Width mm 198, 178 198, 178 198, 178
Middle Mullion Width Fixed T mm 95
Design Linear Design [LD] Linear Design [LD] Linear Design [LD]
PROPERTIES
- - -
Max Sash Height mm 3500 3500 3500
Max Sash Width mm 3000 3000 3000
Max Sash Weight kg 440 440 440
Max Glass Thickness mm 46 46 46
Mechanism Type Lift & Slide/Sliding Lift & Slide Lift & Slide
Surface Finishings All All All
PERFORMANCE
- - -
Uf Value (≥) 2.8 2.7 2.8
Air Permeability Class 4 Class 4 Class 4
Water Tightness E1200 9A 7A
Wind Load Resistance C2/B3 C5/B5 B3
Sound Reduction 45
Operating Force Class 1 Class 2
ELVIAL SL50 HI² CLASSIC ESSENCE SL50 HI² FLAT EDITION
ELVIAL SL50 HI² CLASSIC ESSENCE SL50 HI² FLAT EDITION
DESIGN
- -
Sash Depth mm 50 50
Visible Height Standard Edition mm 125|110, 109|94 118
Visible Height Infloor Edition mm 80, 64 89
Middle Mullion Width Successive mm 98, 48, 25 98, 48, 25
Meeting Stile Construction Width mm 184, 152 184
Middle Mullion Width Fixed T mm 98, 48
Design Linear Design [LD] Linear Design [LD]
PROPERTIES
- -
Max Sash Height mm 3500 3500
Max Sash Width mm 3000 3000
Max Sash Weight kg 400 400
Max Glass Thickness mm 36, 34 36, 34
Mechanism Type Lift & Slide/Sliding Lift & Slide
Surface Finishings All All
PERFORMANCE
- -
Uf Value (≥) 2.32 2.32
Uw value (=) 1.35 1.42
Air Permeability Class 4 Class 4
Water Tightness E900 E900
Wind Load Resistance B2 B2
Sound Reduction 44 44
Operating Force Class 1 Class 1
ELVIAL SL46 SI² CLASSIC ELVIAL SL46 SI² FLAT EDITION
ELVIAL SL46 SI² CLASSIC ELVIAL SL46 SI² FLAT EDITION
DESIGN
- -
Sash Depth mm 46 46
Visible Height Standard Edition mm 121.8 98.8
Visible Height Infloor Edition mm 77.3
Middle Mullion Width Successive mm 89, 56 89, 56
Meeting Stile Construction Width mm 189 189
Middle Mullion Width Fixed T mm 56
Design LINEAR Design [LD] LINEAR Design [LD]
PROPERTIES
- -
Max Sash Height mm 2.800 2.800
Max Sash Width mm 2.000 2.000
Max Sash Weight kg 400 400
Max Glass Thickness mm 30 30
Mechanism Type Lift&Slide / Sliding Lift&Slide / Sliding
Surface Finishings All All
PERFORMANCE
- -
Uf Value (≥) 4.1 3.4
Air Permeability Class 4 Class 4
Water Tightness 4A 7A
Wind Load Resistance C2/B2 C2/B2
Sound Reduction 39 38
Operating Force
ENERGY
Uf value ( ≥)
EN ISO 10077-2
The Uf value measures the heat flow. The lower the Uf , the more efficient the profile you have chosen.
Air Permeability*
EN 1026; EN 12207
1
(150 Pa)
2
(300 Pa)
3
(600 Pa)
4
(600 Pa)
Water Tightness**
EN 1027;EN 12208
4A
(150 Pa)
5A
(200 Pa)
6A
(250 Pa)
7A
(300 Pa)
8A
(450 Pa)
9A
(600 Pa)
E750
(750 Pa)
E1050
(1050 Pa)
E1200
(1200 Pa)
Wind Load Resistance***
EN 12211; EN 12210
1
(400 Pa)
2
(800 Pa)
3
(1200 Pa)
4
(1600 Pa)
5
(2000 Pa)
E
(>2000Pa)
Wind Load Resistance, frame deflection***
EN 12211; EN 12210
Α
(<l/150)
B
(<l/200)
C
(<l/300)
This table shows classes and values of performances, which can be achieved for specific configurations and opening types.
* The Air permeability is the measure of the ability of closed window or door to resist the uncontrolled flow of air at a certain pressure.
** The Water tightness in a window is its capacity to avoid water penetration.
*** The Wind-load resistance refers to the resistance of the closed doors and windows to wind pressure without any damages and functional impairment.There are up to 6 levels of wind resistance and 3 deflection classes.The higher the number, the stronger the wind-load resistance.
ELVIAL SL46 SI²_MD
ELVIAL SL46 SI²_MD
DESIGN
-
Sash Depth mm 46
Visible Height Standard Edition mm 80
Visible Height Infloor Edition mm 59
Middle Mullion Width Successive mm 56
Design LINEAR Design [LD]
PROPERTIES
-
Max Sash Height mm 2.300
Max Sash Width mm 1.200
Max Sash Weight kg 100
Max Glass Thickness mm 30
Mechanism Type INLINE Sliding
Surface Finishings All
ELVIAL SL33 CLASSIC ELVIAL SL33 FLAT EDITION ELVIAL SL33_MD
ELVIAL SL33 CLASSIC ELVIAL SL33 FLAT EDITION ELVIAL SL33_MD
DESIGN
- - -
Sash Depth mm 33 33 33
Visible Height Standard Edition mm 119 101 87
Middle Mullion Width Successive mm 91.7, 56 91.7, 56 78.5, 56, 25
Meeting Stile Construction Width mm 194 194 168
Middle Mullion Width Fixed T mm 56
Design Linear Design [LD] Linear Design [LD] Linear Design [LD]
PROPERTIES
- - -
Max Sash Height mm 2350 2350 2300
Max Sash Width mm 2000 2000 1200
Max Sash Weight kg 200 200 100
Max Glass Thickness mm 27 27 24
Mechanism Type Sliding Sliding Sliding
Surface Finishings All All All
PERFORMANCE
- - -
Uf Value (≥) 3.5 3.5 3.3
Uw value (=) 1.75 1.63 1.72
Air Permeability Class 4 Class 3
Water Tightness 2A
Wind Load Resistance C3/B3 Β2
Sound Reduction
Operating Force